draw.io Diagram border true diagramName fw_reth simpleViewer false width links auto tbstyle top lbox true diagramWidth 491531 revision 12
Useful commands
#> show chassis cluster interfaces
Control link status: Up
Control interfaces:
Index Interface Monitored-Status Internal-SA Security
0 em0 Up Disabled Disabled
Fabric link status: Up
Fabric interfaces:
Name Child-interface Status Security
(Physical/Monitored)
fab0 xe-0/0/17 Up / Up Disabled
fab0
fab1 xe-7/0/17 Up / Up Disabled
fab1
Redundant-ethernet Information:
Name Status Redundancy-group
reth0 Up 1
reth1 Down Not configured
Redundant-pseudo-interface Information:
Name Status Redundancy-group
lo0 Up 0
Interface Monitoring:
Interface Weight Status Redundancy-group
(Physical/Monitored)
xe-7/0/19 255 Up / Up 1
xe-0/0/19 255 Up / Up 1
...