The ports on the first device will be called as usual (ge-0/0/0), but the ports on the second device will start on 7 instead of 0 (on a SRX 1500), so ge-0/0/0 on the second device will be ge-7/0/0.
Cabling
draw.io Diagram border true diagramName FW_HA-cabling simpleViewer false width links auto tbstyle top lbox true diagramWidth 361 revision 2
Useful commands
#> show chassis cluster status
Monitor Failure codes:
CS Cold Sync monitoring FL Fabric Connection monitoring
GR GRES monitoring HW Hardware monitoring
IF Interface monitoring IP IP monitoring
LB Loopback monitoring MB Mbuf monitoring
NH Nexthop monitoring NP NPC monitoring
SP SPU monitoring SM Schedule monitoring
CF Config Sync monitoring RE Relinquish monitoring
IS IRQ storm
Cluster ID: 1
Node Priority Status Preempt Manual Monitor-failures
Redundancy group: 0 , Failover count: 1
node0 255 primary no yes None
node1 1 secondary no yes None
Redundancy group: 1 , Failover count: 3
node0 100 primary yes no None
node1 1 secondary yes no None
...